EVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro

EVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro

I’ve got a BMW 3 Series and wanna use Autel Maxisys MS908S PRO to reset ELV for this 2007 BMW E90 320d diesel. luckily the car started for the customer, and it is running which is good news. There are several warning lights on the dashboard now.EVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro

  • Connect Autel MS908S Pro with BMW OBD2 port, and go to “Service” after auto detect vehicle VIN >> Power train >> CASEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro
  • There are 3 reset functions: reset the starter lock, car access system reset, and reset the internal electric steering lock frequency counter. I will do them all in turn.EVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro
  • Reset Starter Lock
  • Reset starter lock >> Electronic immobilizer(EWS): reset starter lock
  • Turn on terminal 15(ignition), and press “Continue” >> Continue.
  • So it was reset.EVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro

Prompt:

No EWS4 is installed

Select the corresponding service function under:

  • Engine
  • engine electronics or diesel electronics
  • Adjustment functions
  • Digital Motor Electronics (DME)Car Access System(CAS)

The Service function is completed.

Car Access System Reset

  • Return to press “Car access system reset” >> Car access system reset
  • Resetting the car access system (CAS), press “Continue”.
  • The car access system(CAS) was reset, service function was completed. Press “Continue”.
  • Reset Internal Electric Steering Lock Frequency CounterEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro
  • Go back to press “Reset internal electric steering lock frequency counter” >> Reset the internal electric steering lock fault counter.
  • The internal ELV fault counter must be reset and a control unit reset performed after replacing the electric steering lock.
  • Note: this service function must be performed only after replacing the electric steering lock.
  • Press “F1” to continue.
  • Resetting internal ELV(Electronic Steering Lock) fault counter and performing control unit reset. Please wait!
  • The internal ELV(Electronic Steering Lock) fault counter was reset.
  • Upon the completion of the service function, read the fault code memory out of the control unit below and work through as required: car access system.
  • Press “Continue”.EVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro
  • Service function completed, and press “Continue” to complete.
  • All finished! As you can see, the lights on the dashboard were off.EVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S ProEVL Reset for 2007 BMW E90 320D Diesael via Autel MS908S Pro

This is using Autel MS908S Pro Diagnostic Scanner to perform ELV reset for a BMW 3 Series.